China supplier High Pressure Electric Two Stage Rotary Vane Vacuum Pump vacuum pump adapter

Product Description

Product Parameters

Model 2xz-0.5 2xz-1 2xz-2 2xz-4
Pumping Speed L/S(m³/h) 0.5(1.8) 1(3.6) 2(7.2) 4(14.4)
Extreme Pressure(Pa) Partial Pressure ≤6×10-2 ≤6×10-2 ≤6×10-2 ≤6×10-2
Full Pressure ≤1.33 ≤1.33 ≤1.33 ≤1.33
Rotating Speed r/min(50/60Hz) 1400/1700 1400/1700 1400/1700 1400
Voltage(v) 220 220/380 220/380 220/380
Motor Power(kw) 0.18 0.25 0.37 0.55
Inlet Diameter (Outer Diameter)mm G3/8(∅12) G3/8(∅12) G3/4(∅12) G3/4(∅12)
KF-16 KF-16 KF-25 KF-25
Noise(dBA) 62 62 63 64
Oil volume (L) 0.6 0.7 1 1.1
Size(mm) 538*215*360 538*215*360 580*215*367 580*215*367
Gross/Net Weight(kg) 17/16 18/17 22/20 25/22

Model 2xz-2B 2xz-4B 2xz-6B 2xz-8B 2xz-15B 2xz-25B
Pumping Speed L/S(m³/h) 2(7.2) 4(14.4) 6(21.6) 8(28.8) 15(54) 25(90)
Extreme Pressure(Pa) Partial Pressure ≤4×10-2 ≤4×10-2 ≤4×10-2 ≤4×10-2 ≤4×10-2 ≤4×10-2
Full Pressure ≤1 ≤1 ≤1 ≤1 ≤1 ≤1
Rotating Speed r/min(50/60Hz) 1400/1700 1400/1700 1400/1700 1400/1700 1400/1700 1400/1700
Voltage(v) 220/380 220/380 220/380 380 380 380
Motor Power(kw) 0.37 0.55 0.75 1.5 1.5 2.2
Inlet Diameter (Outer Diameter)mm G3/4 G3/4 ∅30 ∅40 ∅40 ∅50
KF-25 KF-25 KF-25 KF-40 KF-40 KF-50
Noise(dBA) 65 66 68 70 72 74
Oil volume (L) 0.8 0.95 1-1.2 2.3-2.5 2.8-3.3 5.5-6.5
Size(mm) 580*215*367 580*215*367 670*240*320 720*270*390 770*270*390 900*320*550
Gross/Net Weight(kg) 22/20 25/22 46/40 68/52 75/62 90/70

Product Description

Rotary Vane Vacuum Pump is the basic equipment used to remove gas from sealed containers.  It can be used alone, also can be used for booster pump, diffusion pump, molecular pump before the pump, maintenance pump, titanium pump pre-pumping pump,  It can be used for vacuum drying, CHINAMFG drying, vacuum degassing, vacuum packaging, vacuum adsorption, vacuum forming, coating, food packaging, printing, sputtering, vacuum casting, instruments, instruments, refrigerators, air conditioning lines and laboratories and other vacuum operations and supporting use.

· Due to the thorough low noise design and precision machining, so as to achieve low noise
· Specially designed gas valve is prepared to prevent the pump oil from mixing with water and prolong the service time of the pump oil
· Adopt similar product design, small size, light weight, low noise, easy to start
· Equipped with vacuum drying oven, freeze-drying machine, printing machinery
· It can be equipped with small-caliber adapter, KF interface and flange interface

Application
· Rotary Vane Vacuum Pump corollary use with freezer dryer to reach vacuum state, it’s an essential corollary equipment in medicine CHINAMFG drying, biology, food industry and agricultural products deep processing
· Rotary Vane Vacuum Pump corollary use with vacuum drying oven for maintaining vacuum state inside the oven, they mainly applies in powder drying and baking in vacuum condition

Company Profile

Packaging & Shipping

FAQ

Q1. What is your products range?
• Industry water chiller, recirculating cooling chiller, rotary evaporator, alcohol recovery equipment, short path distillation kit, glass molecular distillation equipment, falling film evaporator, jacketed glass reactor and other lab equipment.

Q2. Are you trading company or manufacturer?
• We are professional manufacture of lab equipment and we have our own factory.

Q3. Do you provide samples? Is it free?

• Yes, we could offer the sample. Considering the high value of our products, the sample is not free, but we will give you our best price including shipping cost.

Q4. Do you have warranty?
• Yes, we offer 1 year warranty for the spare part.

Q5. How long is your delivery time?
• Generally it is within 7 working days after receiving the payment if the goods are in stock. Or it is 15 working days if thegoods are not in stock, depending on order quantity.

Q6. What is your terms of payment?
• Payment≤15,000USD, 100% in advance. Payment≥15,000USD, 70% T/T in advance, balance before shipment.
(If you are concerned about payment security for the first order, we advise you can place Trade Assurance Order via Alibaba. you will get 100% payment refund if we can’t meet agreed delivery time.)

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

After-sales Service: Online Service Support
Warranty: 1 Year
Oil or Not: Oil
Customization:
Available

|

.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}

Shipping Cost:

Estimated freight per unit.







about shipping cost and estimated delivery time.
Payment Method:







 

Initial Payment



Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.

rotary vane pump

What Is the Role of Lubrication in Rotary Vane Pump Operation?

Lubrication plays a critical role in the operation of a rotary vane pump, ensuring its smooth and efficient performance. Here’s a detailed explanation of the role of lubrication in rotary vane pump operation:

– Friction Reduction: The primary function of lubrication is to reduce friction between moving parts within the pump. In a rotary vane pump, the vanes slide in and out of the rotor slots as the rotor rotates. Lubrication forms a thin film between the vanes and the rotor, reducing the friction and allowing smooth movement. This friction reduction minimizes wear and tear on the vanes and rotor, contributing to the longevity of the pump.

– Seal Enhancement: Lubrication also helps in creating a tight seal between the vanes and the pump housing. The lubricant fills any gaps or imperfections, ensuring proper sealing and preventing gas or fluid leakage. This is particularly important for achieving and maintaining the desired vacuum levels in the pump. Effective sealing enhances the pump’s efficiency and performance.

– Heat Dissipation: During operation, a rotary vane pump generates heat due to the friction and compression of gases or fluids. Lubrication helps in dissipating this heat by absorbing and carrying it away from the critical components of the pump. It prevents excessive heat buildup that can lead to component damage or reduced performance. Proper lubrication ensures that the pump operates within the desired temperature range.

– Wear Protection: The lubricant forms a protective layer on the surfaces of the vanes, rotor, and other moving parts. This layer acts as a barrier, minimizing direct metal-to-metal contact and reducing wear and tear. It helps prevent damage to the vanes and rotor caused by friction and ensures the longevity of these components. Lubrication also protects against corrosion and helps maintain the overall integrity of the pump.

– Noise Reduction: Lubrication contributes to noise reduction in a rotary vane pump. The smooth movement facilitated by the lubricant minimizes vibrations and eliminates or reduces unwanted noise generated during operation. This is particularly important in applications where low noise levels are desired, such as laboratory or medical settings.

– Performance Optimization: Proper lubrication is crucial for maintaining the pump’s performance and efficiency. It ensures that the pump operates with minimal resistance and energy loss, allowing it to achieve the desired vacuum levels or fluid flow rates effectively. Lubrication helps optimize the pump’s overall performance and contributes to its reliability and effectiveness in various applications.

It’s important to note that using the correct type of lubricant specified by the pump manufacturer is essential. Different rotary vane pumps may have specific lubrication requirements, including the type of lubricant and recommended lubrication intervals. Adhering to these guidelines ensures that the lubrication effectively fulfills its role and maintains the pump’s optimal operation.

rotary vane pump

How Do You Maintain and Service a Rotary Vane Pump?

Maintaining and servicing a rotary vane pump is essential to ensure its optimal performance and prolong its operational life. Here’s a detailed explanation of the maintenance and servicing procedures for a rotary vane pump:

– Regular Inspection: Perform regular visual inspections of the pump to check for any signs of wear, leaks, or damage. Inspect the pump housing, vanes, seals, and connections. Look for any loose or worn parts that may require attention.

– Lubrication: Proper lubrication is crucial for the smooth operation of a rotary vane pump. Follow the manufacturer’s guidelines regarding the type and frequency of lubrication. Typically, the pump requires lubrication with a suitable oil or grease. Ensure that the lubrication level is adequate, and monitor the condition of the lubricant. Replace or replenish the lubricant as recommended.

– Vane Replacement: The vanes in a rotary vane pump can wear down over time and may need to be replaced periodically. Inspect the vanes regularly and look for signs of wear, such as cracks or reduced thickness. Replace the vanes if necessary, following the manufacturer’s instructions.

– Cleaning: Keep the pump and its components clean to prevent the buildup of debris or contaminants. Use a suitable cleaning agent and a soft cloth or brush to clean the pump housing, vanes, and other parts. Avoid using harsh chemicals or abrasive materials that may damage the pump surfaces.

– Filter Maintenance: If the rotary vane pump has an inlet filter, inspect and clean or replace it regularly. The filter prevents debris from entering the pump and affecting its performance. Follow the manufacturer’s recommendations for filter maintenance and replacement intervals.

– Seals and Gaskets: Check the seals and gaskets of the pump for signs of wear or leakage. Replace any damaged or worn seals to maintain proper sealing and prevent fluid or gas leaks.

– Motor and Electrical Connections: Inspect the motor and electrical connections of the pump for any loose or damaged wires. Ensure that the electrical connections are secure and free from corrosion. If any issues are found, consult a qualified technician or electrician for repairs.

– Operating Conditions: Ensure that the pump is operated within its specified operating conditions. Avoid subjecting the pump to excessive temperatures, pressures, or fluid viscosity that may exceed its capabilities. Adhere to the recommended operating parameters to prevent premature wear or damage to the pump.

– Service and Calibration: Periodically, consider having the rotary vane pump serviced and calibrated by a qualified technician. This ensures that the pump is operating at its optimal performance and accuracy. The technician can perform maintenance tasks, inspect internal components, and make any necessary adjustments or repairs.

It’s important to consult the manufacturer’s guidelines and recommendations specific to your rotary vane pump model for detailed maintenance and servicing instructions. Adhering to these guidelines and performing regular maintenance will help keep the pump in good working condition and extend its service life.